Solid Loop Lifters

Loading Information

ASC Item #
Steel Designation
Bar Diameter (in)
Anchor Emb. Depth (in)
Anchor Height (in)
Anchor Length (in)
Tension Edge Distance (in)
Tension Capacity 90 (lbs)
Min space Between Achors (in)
Min Member Thickness (in)
Concrete Strength (psi)
A1064
0.375
3.75
5.50
5.50
7.00
3500
14.00
5.00
4000
A36
0.375
4.00
8.50
5.50
7.00
3750
14.00
5.00
4000
7.00
11.00
22.00
8.00
A1064
0.375
4.00
7.00
4000
14.00
5.00
7.00
12.00
4500
24.00
8.00
A36
0.500
7.75
9.75
6.38
13.00
6250
26.00
9.00
4000
A1064
A1064
0.625
5.00
11.00
4.00
8.50
6500
17.00
6.00
4000
7.00
12.00
9000
24.00
8.00
A36
0.625
8.00
12.00
4.00
13.00
7500
26.00
9.00
4000
A1064
5.00
9.00
6500
18.00
6.00
7.00
12.00
9500
24.00
8.00
8.75
15.00
10000
20.00
10.00
A36
0.750
5.50
14.00
12.00
9.50
6625
19.00
7.00
4000
7.00
12.00
8750
24.00
8.00
9.00
15.00
11125
30.00
10.00
A36
1.000
14.00
19.00
5.75
21.00
17750
42.00
15.00
4000

⅜” x 5½” DEFORMED WIRE SOLID LOOP LIFTER

POWDER EPOXY COATED
(USA) DOMESTIC STEEL AND AMERICAN FABRICATED
ITEM # 375-550-DW

LOAD RATINGS WERE ESTABLISHED WHEN THE ⅜” x 5½” DEFORMED WIRE SOLID LOOP
LIFTER WAS EMBEDDED THE MINIMUM DEPTH INTO 4,000 PSI CONCRETE.

Concrete Strength
Wall/Slab Thickness
Anchor Embedment Depth
Tension Straight Up Rating
Min. Tension Edge Distance
Min. Space Between Anchors
4,000 psi
5″
3¾ “
3,500 LBS
7″
14″

⅜” x 8½” SOLID LOOP LIFTER

POWDER EPOXY COATED
(USA) DOMESTIC STEEL ANDAMERICAN FABRICATED
ITEM # 375-850
PATENT # D615,849

LOAD RATINGS ESTABLISHED WHEN THE ½” D-ANCHOR WAS EMBEDDED INTO 4,000 PSI CONCRETE USING A RECESS POCKET PLACING TOP OF THE ANCHOR ¾” BELOW THE SURFACE.
LOAD RATINGS COMPLY WITH OSHA 1926.704 (C) 4:1 SAFETY FACTOR

Concrete Strength
Wall/Slab Thickness
Anchor Embedment Depth
Tension Straight Up Rating
Min. Tension Edge Distance
Min. Space Between Anchors
4,000 psi
5″
4 “
3,500 LBS
7″
14″
4,000 psi
8″
7 “
3,500 LBS
11″
22″

⅜” x 8½” DEFORMED WIRE SOLID LOOP LIFTER

POWDER EPOXY COATED
(USA) DOMESTIC STEEL AND AMERICAN FABRICATED
ITEM # 375-850-DW
PATENT # D615,849

LOAD RATINGS ESTABLISHED WHEN THE ½” D-ANCHOR WAS EMBEDDED INTO 4,000 PSI CONCRETE USING A RECESS POCKET PLACING TOP OF THE ANCHOR ¾” BELOW THE SURFACE.
LOAD RATINGS COMPLY WITH OSHA 1926.704 (C) 4:1 SAFETY FACTOR

Concrete Strength
Wall/Slab Thickness
Anchor Embedment Depth
Tension Straight Up Rating
Min. Tension Edge Distance
Min. Space Between Anchors
4,000 psi
5″
4 “
3,500 LBS
7″
14″
4,000 psi
8″
7 “
3,500 LBS
11″
22″

½” x 9¾” SOLID LOOP LIFTER

POWDER EPOXY COATED
(USA) DOMESTIC STEEL AND AMERICAN FABRICATED
ITEM # 500-975
PATENT # D615,849

LOAD RATINGS WERE ESTABLISHED WHEN THE ½” x 9¾” SOLID LOOP LIFTER WAS EMBEDDED IN THE MINIMUM DEPTH OF 7¾” INTO THE CONCRETE

Concrete Strength
Wall/Slab Thickness
Anchor Embedment Depth
Tension Straight Up Rating
Min. Tension Edge Distance
Min. Space Between Anchors
2,000 psi
9″
7¾”
5,500 LBS
13″
26″
4,000 psi
9″
7¾”
6,250 LBS
13″
26″

½” x 9¾” DEFORMED WIRE SOLID LOOP LIFTER

POWDER EPOXY COATED
(USA) DOMESTIC STEEL AND AMERICAN FABRICATED
ITEM # 500-975-DW
PATENT # D615,849

LOAD RATINGS WERE ESTABLISHED WHEN THE ½” x 9¾” DEFORMED WIRE SOLID LOOP LIFTER WAS EMBEDDEDTHE MINIMUMDEPTH OF 7¾” INTO 4,000 PSI CONCRETE. LOAD RATINGS COMPLY WITH OSHA 1926.704 (C) 4:1 SAFETY FACTOR

Concrete Strength
Wall/Slab Thickness
Anchor Embedment Depth
Tension Straight Up Rating
Min. Tension Edge Distance
Min. Space Between Anchors
4,000 psi
9″
7¾”
6,250 LBS
13″
26″

⅝” x 12” SOLID LOOP LIFTER

POWDER EPOXY COATED
(USA) DOMESTIC STEEL ANDAMERICAN FABRICATED
ITEM # 625-120
PATENT # D615,849

LOAD RATINGS WERE ESTABLISHED WHEN THE ⅝” x 12” SOLID LOOP LIFTER WAS EMBEDDED THE MINIMUM DEPTH OF 8” INTO 4,000 PSI CONCRETE. LOAD RATINGS COMPLY WITH OSHA 1926.704 (C) 4:1 SAFETY FACTOR

Concrete Strength
Wall/Slab Thickness
Anchor Embedment Depth
Tension Straight Up Rating
Min. Tension Edge Distance
Min. Space Between Anchors
4,000 psi
9″
8″
7,500 LBS
13″
26″

⅝” x 12” DEFORMED WIRE SOLID LOOP LIFTER

POWDER EPOXY COATED
(USA) DOMESTIC STEEL AND AMERICAN FABRICATED
ITEM # 625-120-DW
PATENT # D615,849

LOAD RATINGS WERE ESTABLISHED WHEN THE ⅝” x 12” DEFORMED WIRE SOLID LOOP LIFTER WAS EMBEDDED THE MINIMUM DEPTH INTO 4,000 PSI CONCRETE. LOAD RATINGS COMPLY WITH OSHA 1926.704 (C) 4:1 SAFETY FACTOR

Concrete Strength
Wall/Slab Thickness
Anchor Embedment Depth
Tension Straight Up Rating
Min. Tension Edge Distance
Min. Space Between Anchors
4,000 psi
6″
5″
6,500 LBS
9″
18″
4,000 psi
8″
7 “
9,500 LBS
12″
24″
4,000 psi
10″
8¾”
10,000 LBS
15″
30″

¾” x 14” SOLID LOOP LIFTER

POWDER EPOXY COATED
(USA) DOMESTIC STEEL AND AMERICAN FABRICATED
ITEM # 750-140-120

LOAD RATINGS WERE ESTABLISHED WHEN THE ¾” x 14″ SOLID LOOP LIFTER WAS EMBEDDED INTO 4,000 PSI CONCRETE. LOAD RATINGS COMPLY WITH OSHA 1926.704 (C) 4:1 SAFETY FACTOR

Concrete Strength
Wall/Slab Thickness
Anchor Embedment Depth
Tension Straight Up Rating
Min. Tension Edge Distance
Min. Space Between Anchors
4,000 psi
5″
4 “
3,500 LBS
7″
14″
4,000 psi
8″
7 “
3,500 LBS
11″
22″

1” x 19” DEFORMED WIRE SOLID LOOP LIFTER

POWDER EPOXY COATED
(USA) DOMESTIC STEEL AND AMERICAN FABRICATED
ITEM # 1000-1900

LOAD RATINGS ESTABLISHED WHEN THE 1″ X 19″ SOLID LOOP LIFTER WAS EMBEDDED THE MINIMUM DEPTH OF 14″ INTO 4,000 PSI CONCRETE .
LOAD RATINGS COMPLY WITH OSHA 1926.704 (C) 4:1 SAFETY FACTOR

Concrete Strength
Wall/Slab Thickness
Anchor Embedment Depth
Tension Straight Up Rating
Min. Tension Edge Distance
Min. Space Between Anchors
4,000 psi
15″
14″
17,750 LBS
21″
42″