Pulling/Lifting Irons
Loading Information
Item Number | Iron Size | Point A | Point B | Point C | Minimum Embedment Depth | Concrete Strength | Load Rating Tension Stright Up |
---|---|---|---|---|---|---|---|
3/8″ – 7 Wire 270 Grade PC Strand – Pulling/Lifting Irons & Waste Block Lifters | |||||||
3/8″ x 5 1/2″ | 5 1/2″ | 34″ | 12″ | 3″ | 4,000 PSI | 5,000 Lbs. | |
3/8″ x 44″ | 44″ | 36″ | 10″ | 37 1/2″ | 4,000 PSI | 9,500 Lbs. | |
3/8″ x 51″ | 51″ | 37″ | 10″ | 37 1/2″ | 4,000 PSI | 9,500 Lbs. | |
1/2″ – 7 Wire 270 Grade PC Strand – Pulling/Lifting Irons & Waste Block Lifters | |||||||
1/2″ x 3 1/2″ | 3 1/2″ | 15″ | 5 1/2″ | 1 3/4″ | 4,000 PSI | 2,500 Lbs. | |
1/2″ x 6″ | 6″ | 18″ | 6″ | 4 1/4″ | 4,000 PSI | 2,800 Lbs. | |
1/2″ x 7″ | 7″ | 24 1/2″ | 8″ | 4 1/4″ | 4,000 PSI | 3,000 Lbs. | |
1/2″ x 9 1/2″ | 9 1/2″ | 27″ | 8″ | 4 1/4″ | 4,000 PSI | 3,200 Lbs. | |
1/2″ x 10 1/2″ | 10 1/2″ | 28″ | 8″ | 5″ | 4,000 PSI | 4,000 Lbs. | |
1/2″ x 12″ | 12″ | 29″ | 8″ | 7″ | 4,000 PSI | 7,400 Lbs. | |
1/2″ x 15″ | 15″ | 31 1/2″ | 8″ | 9″ | 4,460 PSI | 9,800 Lbs. | |
1/2″ x 18″ | 18″ | 34″ | 8″ | 12″ | 4,460 PSI | 13,800 Lbs. | |
1/2″ x 44″ | 44″ | 44″ | 9″ | 37 1/2″ | 4,000 PSI | 14,000 Lbs. | |
1/2″ x 44″ Double | 44″ | 44″ | 9″ | 37 1/2″ | 4,000 PSI | 29,250 Lbs. | |
1/2″ x 51″ | 51″ | 52″ | 9″ | 37 1/2″ | 4,000 PSI | 14,000 Lbs. |
⅜” x 5½” PULLING/LIFTING IRON WITH GALVANIZED CONDUIT COVERING
(USA) DOMESTIC STEEL AND AMERICAN FABRICATED
ITEM # 375-550
ONLY FOR USE IN PROPERLY STEEL REINFORCED CONCRETE
NOT FOR USE IN NON-REINFORCED CONCRETE
***PULLING/LIFTING IRON IS TO BE USED IN TENSION STRAIGHT UP PULL ONLY***
LOAD RATING WAS ESTABLISHED WHEN THE ⅜” x 5½” PULLING/LIFTING IRON WAS
EMBEDDED THE MINIMUM DEPTH OF 3” IN 4,000 PSI CONCRETE WITH STEEL
REINFORCEMENT OF ½” GRADE 60 A615 REBAR ON 12” x 12” SPACING WHERE THE
HAUNCHES OF THE PULLING/LIFTING IRON WERE SECURELY UNDER.
LOAD RATINGS COMPLY WITH OSHA 1926.704 (C) 4:1 SAFETY FACTOR
Concrete Strength | Tension Straight Up |
---|---|
4,000 PSI | 5,000 LBS |
*PULLING IRON/SEPTIC TANK LIFTERS ARE NOT TREATED TO RESIST CORROSION IN ANY MATTER
⅜” x 44” PULLING/LIFTING IRON WITH GALVANIZED CONDUIT COVERING
(USA) DOMESTIC STEEL AND AMERICAN FABRICATED
ITEM # 375-4400
***PULLING/LIFTING IRON IS TO BE USED IN TENSION STRAIGHT UP PULL ONLY***
LOAD RATING IS DEPENDENT UPON THE PULLING/LIFTING IRON BEING EMBEDDED
A MINIMUM OF 37.5” INTO 4,000 PSI CONCRETE
LOAD RATINGS COMPLY WITH OSHA 1926.704 (C) 4:1 SAFETY FACTOR
Concrete Strength | Tension Straight Up |
---|---|
4,000 PSI | 9,500 LBS |
*PULLING IRON/SEPTIC TANK LIFTERS ARE NOT TREATED TO RESIST CORROSION IN ANY MATTER
WITH GALVANIZED CONDUIT COVERING
(USA) DOMESTIC STEEL AND AMERICAN FABRICATED
ITEM # 375-5100
⅜” x 51” PULLING/LIFTING IRON WITH GALVANIZED CONDUIT COVERING
***PULLING/LIFTING IRON IS TO BE USED IN TENSION STRAIGHT UP PULL ONLY***
LOAD RATING IS DEPENDENT UPON THE PULLING/LIFTING IRON BEING EMBEDDED
A MINIMUM OF 37.5” INTO 4,000 PSI CONCRETE
LOAD RATINGS COMPLY WITH OSHA 1926.704 (C) 4:1 SAFETY FACTOR
Concrete Strength | Tension Straight Up |
---|---|
4,000 PSI | 9,500 LBS |
*PULLING IRON/SEPTIC TANK LIFTERS ARE NOT TREATED TO RESIST CORROSION IN ANY MATTER
½” x 3½” PULLING/LIFTING IRON WITH GALVANIZED CONDUIT COVERING
(USA) DOMESTIC STEEL AND AMERICAN FABRICATED
ITEM # 500-350
ONLY FOR USE IN PROPERLY STEEL REINFORCED CONCRETE
NOT FOR USE IN NON-REINFORCED CONCRETE
***PULLING/LIFTING IRON IS TO BE USED IN TENSION STRAIGHT UP PULL ONLY***
LOAD RATING WAS ESTABLISHED WHEN THE ½” x 3½” PULLING/LIFTING IRON WAS
EMBEDDED INTO THE CONCRETE AT THE MINIMUM DEPTH OF 1¾”.
LOAD RATINGS COMPLY WITH OSHA 1926.704 (C) 4:1 SAFETY FACTOR
Concrete Strength | Tension Straight Up |
---|---|
4,000 PSI | 2,500 LBS |
*PULLING IRON/SEPTIC TANK LIFTERS ARE NOT TREATED TO RESIST CORROSION IN ANY MATTER
½” x 6” PULLING/LIFTING IRON WITH GALVANIZED CONDUIT COVERING
(USA) DOMESTIC STEEL AND AMERICAN FABRICATED
ITEM # 500-600
ONLY FOR USE IN PROPERLY STEEL REINFORCED CONCRETE
NOT FOR USE IN NON-REINFORCED CONCRETE
***PULLING/LIFTING IRON IS TO BE USED IN TENSION STRAIGHT UP PULL ONLY***
LOAD RATING WAS ESTABLISHED WHEN THE ½” x 6” PULLING/LIFTING IRON WAS
EMBEDDED INTO THE CONCRETE AT THE MINIMUM DEPTH OF 4¼”.
LOAD RATINGS COMPLY WITH OSHA 1926.704 (C) 4:1 SAFETY FACTOR
Concrete Strength | Tension Straight Up |
---|---|
4,000 PSI | 2,800 LBS |
*PULLING IRON/SEPTIC TANK LIFTERS ARE NOT TREATED TO RESIST CORROSION IN ANY MATTER
½” x 7” PULLING/LIFTING IRON WITH GALVANIZED CONDUIT COVERING
(USA) DOMESTIC STEEL AND AMERICAN FABRICATED ITEM # 500-700
ONLY FOR USE IN PROPERLY STEEL REINFORCED CONCRETE
NOT FOR USE IN NON-REINFORCED CONCRETE
***PULLING/LIFTING IRON IS TO BE USED IN TENSION STRAIGHT UP PULL ONLY***
LOAD RATING WAS ESTABLISHED WHEN THE ½” x 7” PULLING/LIFTING IRON WAS
EMBEDDED INTO THE CONCRETE AT THE MINIMUM DEPTH OF 4¼”.
LOAD RATINGS COMPLY WITH OSHA 1926.704 (C) 4:1 SAFETY FACTOR
Concrete Strength | Tension Straight Up |
---|---|
4,000 PSI | 3,000 LBS |
*PULLING IRON/SEPTIC TANK LIFTERS ARE NOT TREATED TO RESIST CORROSION IN ANY MATTER
½” x 9½” PULLING/LIFTING IRON WITH GALVANIZED CONDUIT COVERING
(USA) DOMESTIC STEEL AND AMERICAN FABRICATED ITEM # 500-950
ONLY FOR USE IN PROPERLY STEEL REINFORCED CONCRETE
NOT FOR USE IN NON-REINFORCED CONCRETE
***PULLING/LIFTING IRON IS TO BE USED IN TENSION STRAIGHT UP PULL ONLY***
LOAD RATING WAS ESTABLISHED WHEN THE ½” x 9½” PULLING/LIFTING IRON WAS EMBEDDED INTO THE CONCRETE AT THE MINIMUM DEPTH OF 5¼”.
LOAD RATINGS COMPLY WITH OSHA 1926.704 (C) 4:1 SAFETY FACTOR
Concrete Strength | Tension Straight Up |
---|---|
4,000 PSI | 3,200 LBS |
*PULLING IRON/SEPTIC TANK LIFTERS ARE NOT TREATED TO RESIST CORROSION IN ANY MATTER
½” x 10½” PULLING/LIFTING IRON WITH GALVANIZED CONDUIT COVERING
(USA) DOMESTIC STEEL AND AMERICAN FABRICATED ITEM # 500-1050
ONLY FOR USE IN PROPERLY STEEL REINFORCED CONCRETE
NOT FOR USE IN NON-REINFORCED CONCRETE
***PULLING/LIFTING IRON IS TO BE USED IN TENSION STRAIGHT UP PULL ONLY***
LOAD RATING WAS ESTABLISHED WHEN THE ½” x 10½” PULLING/LIFTING IRON WAS EMBEDDED INTO THE CONCRETE AT THE MINIMUM DEPTH OF 5”.
LOAD RATINGS COMPLY WITH OSHA 1926.704 (C) 4:1 SAFETY FACTOR
Max. Load Rating at 1,500 PSI | Max. Load Rating at 2,500 PSI | Max Load Rating at 4,000 PSI |
---|---|---|
3,400 LBS | 3,800 LBS | 4,000 LBS |
*PULLING IRON/SEPTIC TANK LIFTERS ARE NOT TREATED TO RESIST CORROSION IN ANY MATTER
½” x 12” PULLING/LIFTING IRON WITH GALVANIZED CONDUIT COVERING
(USA) DOMESTIC STEEL AND AMERICAN FABRICATED ITEM # 500-1200
ONLY FOR USE IN PROPERLY STEEL REINFORCED CONCRETE
NOT FOR USE IN NON-REINFORCED CONCRETE
***PULLING/LIFTING IRON IS TO BE USED IN TENSION STRAIGHT UP PULL ONLY***
LOAD RATING WAS ESTABLISHED WHEN THE ½” x 12” PULLING/LIFTING IRON WAS EMBEDDED INTO THE CONCRETE AT THE MINIMUM DEPTH OF 7”.
LOAD RATINGS COMPLY WITH OSHA 1926.704 (C) 4:1 SAFETY FACTOR
Max. Load Rating at 1,500 PSI | Max. Load Rating at 2,500 PSI | Max Load Rating at 4,000 PSI |
---|---|---|
4,500 LBS | 6,300 LBS | 7,400 LBS |
*PULLING IRON/SEPTIC TANK LIFTERS ARE NOT TREATED TO RESIST CORROSION IN ANY MATTER
½” x 15” PULLING/LIFTING IRON WITH GALVANIZED CONDUIT COVERING
(USA) DOMESTIC STEEL AND AMERICAN FABRICATED ITEM # 500-1500
ONLY FOR USE IN PROPERLY STEEL REINFORCED CONCRETE
NOT FOR USE IN NON-REINFORCED CONCRETE
***PULLING/LIFTING IRON IS TO BE USED IN TENSION STRAIGHT UP PULL ONLY***
LOAD RATING WAS ESTABLISHED WHEN THE ½” x 15” PULLING/LIFTING IRON WAS EMBEDDED INTO THE CONCRETE AT THE MINIMUM DEPTH OF 9”.
LOAD RATINGS COMPLY WITH OSHA 1926.704 (C) 4:1 SAFETY FACTOR
Concrete Strength | Maximum Load Rating |
---|---|
4,460 PSI | 9,800 LBS |
*PULLING IRON/SEPTIC TANK LIFTERS ARE NOT TREATED TO RESIST CORROSION IN ANY MATTER
½” x 18” PULLING/LIFTING IRON WITH GALVANIZED CONDUIT COVERING
(USA) DOMESTIC STEEL AND AMERICAN FABRICATED ITEM # 500-1800
ONLY FOR USE IN PROPERLY STEEL REINFORCED CONCRETE
NOT FOR USE IN NON-REINFORCED CONCRETE
***PULLING/LIFTING IRON IS TO BE USED IN TENSION STRAIGHT UP PULL ONLY***
LOAD RATING WAS ESTABLISHED WHEN THE ½” x 18” PULLING/LIFTING IRON WAS EMBEDDED INTO THE CONCRETE AT THE MINIMUM DEPTH OF 12”.
LOAD RATINGS COMPLY WITH OSHA 1926.704 (C) 4:1 SAFETY FACTOR
Concrete Strength | Maximum Load Rating |
---|---|
4,460 PSI | 13,800 LBS |
*PULLING IRON/SEPTIC TANK LIFTERS ARE NOT TREATED TO RESIST CORROSION IN ANY MATTER
½” x 44” PULLING/LIFTING IRON WITH GALVANIZED CONDUIT COVERING
(USA) DOMESTIC STEEL AND AMERICAN FABRICATED ITEM # 500-4400
***PULLING/LIFTING IRON IS TO BE USED IN TENSION STRAIGHT UP PULL ONLY***
LOAD RATING IS DEPENDENT UPON THE PULLING/LIFTING IRON BEING EMBEDDED
A MINIMUM OF 37.5” INTO 4,000 PSI CONCRETE
LOAD RATINGS COMPLY WITH OSHA 1926.704 (C) 4:1 SAFETY FACTOR
Concrete Strength | Tension Straight Up |
---|---|
4,000 PSI | 14,000 LBS |
*PULLING IRON/SEPTIC TANK LIFTERS ARE NOT TREATED TO RESIST CORROSION IN ANY MATTER
½” x 44” DOUBLE PULLING/LIFTING IRON WITH GALVANIZED CONDUIT COVERING
(USA) DOMESTIC STEEL AND AMERICAN FABRICATED
ITEM # 500-4400-00
***PULLING/LIFTING IRON IS TO BE USED IN TENSION STRAIGHT UP PULL ONLY*** LOAD RATING IS DEPENDENT UPON THE PULLING/LIFTING IRON BEING EMBEDDED
A MINIMUM OF 37.5” INTO 4,000 PSI CONCRETE
LOAD RATINGS COMPLY WITH OSHA 1926.704 (C) 4:1 SAFETY FACTOR
Concrete Strength | Tension Straight Up |
---|---|
4,000 PSI | 29,250 LBS |
*PULLING IRON/SEPTIC TANK LIFTERS ARE NOT TREATED TO RESIST CORROSION IN ANY MATTER
½” x 51” PULLING/LIFTING IRON WITH GALVANIZED CONDUIT COVERING
(USA) DOMESTIC STEEL AND AMERICAN FABRICATED
ITEM # 500-5100
***PULLING/LIFTING IRON IS TO BE USED IN TENSION STRAIGHT UP PULL ONLY***
LOAD RATING IS DEPENDENT UPON THE PULLING/LIFTING IRON BEING EMBEDDED
A MINIMUM OF 37½” INTO 4,000 PSI CONCRETE
LOAD RATINGS COMPLY WITH OSHA 1926.704 (C) 4:1 SAFETY FACTOR
Concrete Strength | Tension Straight Up |
---|---|
4,000 PSI | 14,000 LBS |
*PULLING IRON/SEPTIC TANK LIFTERS ARE NOT TREATED TO RESIST CORROSION IN ANY MATTER